147 Call Toll Free 1-800-328-2724 email: sales@waytekwire.com
WARNING: Cancer and Reproductive Harm www.P65Warnings.ca.gov
Battery Management
MASTER BATTERY DISCONNECT SWITCHES
Metal Bodied
Master battery disconnect switches are installed in electrical systems allowing the operator or technician to completely disconnect the electrical current running through your commercial vehicle or piece of equipment. Being able to isolate the flow of electricity has many safety, security, and cost-saving benefits. SPST switches disconnect the battery circuit only, while DPST options will disconnect the battery and the alternator or generator field circuit as well Plated steel case with a die-cast lever and copper contacts
3
/
4
" through hole installation Off-On circuit
Stock No. Type Continuous Rating Intermittent Rating Stud Size
44245 SPST 300A 2000A, 30 sec on, 5 min off (2)
1
/ 2" 44243* SPST 175A at 6VDC-36VDC 800A at 6VDC-36VDC, 15 sec on, 5 min off (2)
3
/ 8" 44242* SPST 40A at 6VDC, 20A at 12VDC 250A at 6VDC, 125A at 12VDC (2)
3
/ 8" 44244 DPST 300A 2000A, 30 sec on, 5 min off (2)
3
/ 8" (2) #10
* UL Listed 375m
6-36VDC
LEVER AND FLANGE PLATE FOR PADLOCK
Stock No. 44519
(Littelfuse No. 24505)
For use with Cole Hersee lever-actuated master disconnect switches with a
3
/4" diameter (19.1 mm) mounting stem: Stock No. 44242, 44243, 44244 Recommend the use of a padlock with a
5
/16" (7.9 mm) diameter shackle Includes: locking lever, bracket, and (2) #10-32 x
3
/8" screws Stock No. 43921
(Littelfuse No. 75903)
Intermittent rating: 1000A intermittent, 15 seconds On, 5 minutes Off Two-positions: Off-On 6-36V Contacts: brass Contacts: (2)
3
/8"-24 and (2) #10-32 stud terminals
BATTERY DISCONNECT SWITCH
12VDC 125A
Stock No. 43922
(Littelfuse No. 75904-01)
O-ring seal in the operating shaft, gasket sealed terminal insulator and locating pin DPST: will disconnect the battery and the alternator or generator field circuit Intermittent rating: 1000A intermittent, 15 seconds On, 5 minutes Off Two-positions: Off-On Contacts: silver plated Contacts: (2)
3
/8"-24 and (2) #10-32 stud terminals
WEATHER RESISTANT BATTERY DISCONNECT SWITCH
12VDC 125A
MASTER DISCONNECT SWITCH ES
180A continuous or 1,000A inrush One piece die-cast housing is 2
5
/8" dia. and 4
3
/ 8" long Mounting stem is
3
/4" dia. and
1
/ 2" long
Lever Operated
Stock No. 44030
(Pollak No. 51-902)
SPST Off-On for battery circuit only Does not disconnect alternator or generator Comes with face plate Stock No. 44032
3
/8" stud terminals Conforms to UL558
Lever Operated
Stock No. 44031
(Pollak No. 51-904EP)
DPST On-Off for battery and alternator or generator circuit Breaks alternator circuit (Max. of 20A) prior to disconnecting battery
3
/8" and #10-32 stud terminals
Key Operated
Stock No. 44029
(Pollak No. 51-916)
SPST Off-On for battery circuit only Does not disconnect alternator or generator Includes indexing post to prevent rotation
3
/8" stud terminals Conforms to UL558
Face Plate
Stock No. 44032
(Pollak No. 51-303)
For master disconnect switches with Off-On designation Polished aluminum with black letters Includes alignment hole For lever-operated switches Stock No. 44030 & 44031
6-36VDC
Stock No. 44243
Previous Page