177 Call Toll Free 1-800-328-2724 email: sales@waytekwire.com
WARNING: Cancer and Reproductive Harm www.P65Warnings.ca.gov
Power Distribution
Typical 2 position 150 volt unit shown Typical 6 position 30 Amp unit shown
TERMINAL BLOCKS
Double Row Ter mi nal Block
Used for general purpose electronic and electrical work Helps eliminate splicing High density circuitry can be attained to conserve panel space Tin plated brass terminals and zinc plated steel screws Molded from UL rated 94 thermoplastic Dimensions by circuit count Jumper Strip Used to bridge adjacent connections
TERMINAL STRIPS
S W A B D T L C diameter S W A B D T L C diameter S W A B D T L C diameter
150VDC style 300VDC and 30A styles
Push-On Tabs Converts from screw connections
Type For terminal Strip series Flat tab Stock No. 45 Tab Stock No. Tab Width
Push-on Tab 47102 - 47112 37220 37221 .187 47302 - 47312 37250 37251 .250
All dimensions in inches
60 or 75A/600VDC style
Typical Dimensions Type Positions Stock No. L W T D S A B C
30A rating 300VDC max #6-32 screws 2 mounting holes 2 47102 1.40 0.88 0.41 0.31 0.38 0.30 1.12 0.17 3 47103 1.78 0.88 0.41 0.31 0.38 0.30 1.50 0.17 4 47104 2.16 0.88 0.41 0.31 0.38 0.30 1.88 0.17 5 47105 2.53 0.88 0.41 0.31 0.38 0.30 2.25 0.17 6 47106 2.90 0.88 0.41 0.31 0.38 0.30 2.62 0.17 8 47108 3.66 0.88 0.41 0.31 0.38 0.30 3.38 0.17 10 47110 4.40 0.88 0.41 0.31 0.38 0.30 4.12 0.17 12 47112 5.16 0.88 0.41 0.31 0.38 0.30 4.88 0.17 30A rating 300VDC max #6-32 screws 3 mounting holes 2 47302 1.63 1.12 0.56 0.44 0.44 0.35 1.31 0.17 3 47303 2.07 1.12 0.56 0.44 0.44 0.35 1.75 0.17 4 47304 2.51 1.12 0.56 0.44 0.44 0.35 2.18 0.17 5 47305 2.94 1.12 0.56 0.44 0.44 0.35 2.62 0.17 6 47306 3.38 1.12 0.56 0.44 0.44 0.35 3.06 0.17 8 47308 4.25 1.12 0.56 0.44 0.44 0.35 3.93 0.17 10 47310 5.13 1.12 0.56 0.44 0.44 0.35 4.81 0.17 12 47312 6.00 1.12 0.56 0.44 0.44 0.35 5.68 0.17 30A rating 600VDC max #8-32 screws 3 mounting holes 2 47352 2.13 1.33 0.81 0.50 0.56 0.41 1.69 0.21 3 47353 2.69 1.33 0.81 0.50 0.56 0.41 2.25 0.21 4 47354 3.25 1.33 0.81 0.50 0.56 0.41 2.81 0.21 5 47355 3.81 1.33 0.81 0.50 0.56 0.41 3.37 0.21 6 47356 4.37 1.33 0.81 0.50 0.56 0.41 3.94 0.21 8 47358 5.50 1.33 0.81 0.50 0.56 0.41 5.06 0.21 10 47360 6.62 1.33 0.81 0.50 0.56 0.41 6.19 0.21 12 47362 7.75 1.33 0.81 0.50 0.56 0.41 7.31 0.21 75A UL 60A CSA 600VDC max #10-32 screws 3 mounting holes 2 47382 2.51 1.81 0.76 0.63 0.69 0.56 2.06 0.22 3 47383 3.20 1.81 0.76 0.63 0.69 0.56 2.75 0.22 4 47384 3.89 1.81 0.76 0.63 0.69 0.56 3.44 0.22 5 47385 4.58 1.81 0.76 0.63 0.69 0.56 4.13 0.22 6 47386 5.26 1.81 0.76 0.63 0.69 0.56 4.81 0.22 8 47388 6.64 1.81 0.76 0.50 0.69 0.56 6.19 0.22
All dimensions in inches
Terminal Block Hardware
Type For terminal Strip series Stock No.
Jumper 47102 - 47112 37211 47302 - 47312 37212 47352 - 47388 37214*
*
Ring style, not fork type
Stock No. 37214 Stock No. 37211 12-pole Modular design allows larger blocks to be easily cut into smaller circuit sizes Contacts and screws are recessed within the housing to help prevent short circuits Wire protectors prevent stranded wire damage during connection Range of pitch spacing, wire ranges and electrical ratings provide design flexibility to choose the block that best fits the requirements
Stock No. Wire Ga Pitch (P) Amp Volts Length Width Height
47159 22-12 .315 (8mm) 20 600 3.680 (93.47mm) .72 (18.20mm) .68 (17.30mm) 47151 18-10 .394 (10mm) 30 600 4.606 (117.00mm) 1.74 (18.80mm) .76 (19.20mm) 47158 20-8 .472 (12mm) 40 600 5.512 (140.00mm) 1.91 (23.20mm) .83 (21.20mm)
212F (100C) Continuous Stock No. 47158 #10-24 studs spaced
3
/4
" apart Barriers prevent shorting Nuts not included
Stock No. Studs Overall Length Mounting Hole Spacing
47214 4
1
/2
3
/4
47216 6 5
1
/4
47218 8 7
1
/2
6
3
/4
STUD TYPE JUNCTION BLOCK
600VDC 30A
Previous Page